LiFEGAIN CU-HD1

LiFEGAIN CU-HD1   .

cropped-dsc00297_re1.jpg

Description
The CU-HD1 is a medical device that is operated by battery and AC power. This product is a medical device designed to be used by Level 1 and Level 2 emergency medical technicians and medical professionals. This product provides the automated external defibrillation fuction and the manual defibrillation fuction. This product also provides the synchronized cardioversion function, transcutaneous pacing function, and patient monitoring function. This product also has the Synchronized Cardioversion function, Transcutaneous Pacing function, and Patient Monitoring function. This product can be used by emergency medical technician and medical professionals. You can use the functions of the device with simple button operation, and check various information through the screen while using the product. 

Functions and Features

Patient Monitoring (ECG, SpO2, NIBP, Pacer)
Convenient shortcut buttons and switch for using in hospital and emergency
Data transmission using Bluetooth

Specifications

• Exterior View
Dimensions  : 326 x 253 x 356mm (W x L x H)
Weight: 5kg or below (without accessories)

• Display
Type : TFT LCD (including backlights)
Screen Size : 152.4 (W ) x 91.44 (H) mm
Resolution : 800 x 480 (RGB) pixels

• Defibrillator
Operation
Mode : Semi-automatic/ Manual
Defibrillation
Output Waveform: e-cube Biphasic (BTE type)
Output energy: 200 Joules fixed, Manual 1~200J
R-sync defibrillation: transfer of the defibrillation energy synchronized with the R-wave out of QRS of the ECG signal within 60ms.

.• ECG Monitoring Mode
ECG Input: 3-Lead, 5-Lead, 12-Lead
Heart rate display: 30 ~ 300 bpm (Accuracy: 3 bpm)
ECG Size:  5mm/mV, 10mm/mV, 20mm/mV

• Pacer Mode
Pacing Type: (Noninvasive Pacing)
Energy Waveform: Monophasic Rectangular
Pacing Mode: Demand mode, Fixed mode
Energy Magnitude: 5 ~ 200 mA (±5mA)
Pacing Rate: 30~180 ppm (±1.5%)

• SpO2 Pulse Oximetry
Pulse rate: 20~250bpm (±3bpm)
SpO2 value : 1~100% SpO2 (±3digit)
Noninvasive Blood Pressure (NIBP)
Measuring Method: Oscillometric
Systolic Range
-Adult: 40~260 mmHg
-Pediatric: 40~160 mmHg
-Neonate: 40~130 mmHg
Diastolic Range
-Adult: 20~200 mmHg
-Pediatric: 20~120 mmHg
-Neonate: 20~100 mmHg

CU-HD1

.

• Event Storage
External Storage
ECG Data: Maximum 100 data & Store more than 192 hours of events and ECG data
Voice Data: store more than 8 hours.

• Printer
Print Method: Thermal printing
Width: 48mm
Print Rate : 25mm/sed
Printer paper: Width 58mm, Minimum Diameter 40mm.

Accessories
• Standard Package
Device, Adult Pads(1), Pads Adapter Cable(1), ECG Electrode (1Pack), 3-Lead(1), Printer paper(5), SD Card(1), SD Card Reader(1), AC cable(1), Rechargeable battery(1),Test Loader(1), User’s Manual(1)
• Optional Accessories
Sp02 Module set – Probe, Extension Cable(1)
NIBP Module set – Adult, Pediatric, Neonate cuff, Extension Cable (1)
5-Lead ECG Cable(1), 12-Lead ECG cable(1), Pacer(1), paddle(1), Gel(1), EtCO2(1)
Car Cigar Lighter Jack(1), PC Communication Software(1), Carrying Case(1)